This page provides a table listing support for the third party applications that are required to run PhixFlow at major releases:
- A web browser (on the client side)
- A database server
- An application server
Java runtime environment
Note Remember to update your database drivers to be compatible with the version of Java that PhixFlow requires.
The table below also includes any special upgrade instructions that you should be aware of when planning to migrate to a new version. Please check for all special instructions between your current version and the new version. While the upgrade process for PhixFlow itself is quick, please use the table below to determine if you need to plan, with your IT department, upgrades to any other software.
Warning |
---|
We will discontinue support for Oracle 12.1 (Oracle 12c Release 1) at the next major release. |
PhixFlow Major Version | Databases Supported | Tomcat | Java Runtime | Database | Browsers | Special upgrade instructions | ||||
---|---|---|---|---|---|---|---|---|---|---|
Oracle | MS SQL Server | Maria DB | IE1 | Chrome2 | Firefox2 | |||||
7.9 | 12c (12.2 |
.0.1 and 12.1) | 2017 2016 | 10.1 | 8.5 | 8 | Java 8 / JDBC 4.2 API | 11 | 66 | 59 | Warning: This is the last major release to support Oracle 12.1 (Oracle 12c release 1). Mandatory: Due to changes to the logging setup, you must configure two new logging configuration files; see Configure logback.xml and phixflow-logging.xml. | |
---|---|---|---|---|---|---|---|---|---|---|
7.8 | 12c (12.1) | 2017 2016 | 10.1 | 8.5 | 8 | 11 | 66 | 59 | Mandatory: Upgrade to SQL Server 2016 or later. Mandatory: There are incompatible changes at 7.8.0 to the webapp configuration files in $webapp/WEB-INF/classes - simply copying the configuration files from an earlier release will not work. We recommend that you create new configuration files by copying the relevant templates and re-applying the necessary changes. See the release notes for more information on the changes and files affected. | |
7.7 | 12c (12.1) | 2017 2016 2014 2008 | 10.1 | 8.5 | 8 | 11 | 66 | 59 | We will support SQL Server 2008 until the end of 2018. At this point support for this database will be ended. Mandatory: Upgrade to Java 1.8.0_151 or later and ensure that Java is configured to allow unlimited-strength security; see Install Java for details. | |
7.6 | 12c (12.1) | 2017 2016 2014 2008 | 10.1 | 8.5 | 8 | 11 | 66 | 59 | Mandatory: Upgrade to Oracle 12c Mandatory: Upgrade to MariaDB 10.1 We will support SQL Server 2008 until the end of 2018. At this point support for this database will be ended. | |
7.5 | 12c (12.1) 11g | 2016 2014 2012 2008 | 10.1 10.0 | 8.5 | 8 | 11 | 63 | 58 | Advisory: If using Oracle upgrade to version 12c. | |
7.4 | 12c (12.1) 11g | 2016 2014 2012 | 10.1 10.0 | 8.5 | 8 | 11 | 62 | 56 | If using Oracle 12c, update the phixflow-datasource.xml file to resolve an issue that can affect configuration imports; see Oracle 12c - edit phixflow-datasource.xml for details. Excel File Collectors must quote worksheet names if they contain spaces and/or single quotes. This is not handled automatically by the upgrade process. See special notes for Excel file collectors at 7.4.0 for details. | |
7.3 | 12c (12.1) 11g | 2016 2014 2012 | 10.1 10.0 | 8.5 | 8 | 11 | 60 | 55 | Mandatory: Upgrade to Tomcat 8.5 | |
7.2 | 12c (12.1) 11g | 2016 2014 2012 | 10.1 10.0 | 8.5 8 7 | 8 | 11 | 55 | 50 | If using SQL Server, you need to update the SQLServer dialect specified in the | |
7.1 | 12c (12.1) 11g | 2016 2014 2012 | 10.1 10.0 | 8.5 8 7 | 8 | 11 10 | 55 | 50 | Advisory: Upgrade to Tomcat 8.5 Advisory: If using Oracle upgrade to version 12c. | |
7.0 | 12c 11g | 2016 2014 2012 | 10.1 10.0 | 8.5 8 7 | 8 | 11 10 | 53 | 47 | Mandatory: Install Java 8. Advisory: Upgrade to Tomcat 8.5 Advisory: If using Oracle upgrade to version 12c. | |
6.0 | 12c 11g | 2008 R2 | 10.1 10.0 | 8 7 | 7 | 8.0 | 53 | 47 | ||
5.9 | 12c 11g | 2008 R2 | - | 8 7 | 7 | 8.0 | - | - | Please see additional special upgrade instructions for this release at Upgrade 5.9.0 | |
5.8 | 11g | 2008 R2 | - | 7 | 7 | 8.0 | - | - |
1 The use of IE with PhixFlow version 7.0 onwards (i.e. with the Javascript GUI) is not recommended. The GUI has full functionality in this browser, but does not perform as well as in Chrome and Firefox.
...