This page is for system administrators who are upgrading an existing PhixFlow instance from one release to another. This page explains the standard steps that you should always follow.
Warning |
---|
Some releases contain special instructions. When planning an upgrade, please check the special instructions for each intermediate release and follow the additional steps as indicated. |
Planning your Upgrade
Anchor | ||||
---|---|---|---|---|
|
Check Supported Versions and Special Instructions
Please read the System Requirements and Compatibility page. Check for any special upgrade instructions between your current and target versions of PhixFlow.
Ensure that your versions of:
- the database
- Tomcat
- Java
are supported in the planned upgrade.
Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Note |
---|
If any of these items need updating, please contact your IT team several weeks in advance of the planned upgrade. |
Check Java and Database Connectors
If Java needs upgrading, you must verify that any JDBC connectors you have installed to non-standard databases are still supported. The standard databases supported by PhixFlow are Oracle, MS SQL Server and MySQL/ MariaDB. The drivers needed to connect to these databases are shipped with PhixFlow, and connections to external databases through PhixFlow data sources are supported by these drivers; see Datasource.
However, if you have connections to external databases other than these - for example, Netezza, Teradata, DB2 - then you will have installed JDBC drivers for these in the folder [tomcat home]/lib
. You must check that your current version of each installed driver is compatible with the new version of Java, and if not, obtain a new version of the JDBC driver from the supplier.
How to Upgrade
Step 1 Backup your Database
Ensure that you have a recent, full backup of your PhixFlow database. If you need to rollback (see "Rollback Upgrade" below), your PhixFlow configuration and data will revert to this point.
Tip |
---|
We also recommend that you:
|
Step 2 Stop Tomcat and Delete the Work Directory
Stop the Tomcat service.
Note PhixFlow will not be available to users until the upgrade is complete and you restart Tomcat.
Delete the Tomcat
<tomcat base>/work
directory. For example in a Linux installation, enter:Code Block rm -r /opt/tomcat/work
Step 3 Upgrade the Environment
If necessary, upgrade to supported versions of Java, Tomcat and your database: Oracle, SQL Server or MySQL / MariaDB. See Planning your Upgrade, above.
Remember, if you are Upgrading Tomcat, to restore any JDBC drivers needed for any data sources that use database technologies or versions not supported for PhixFlow's own connections. Make sure that any additional JDBC drivers you use are placed in:
Code Block |
---|
[tomcat home]/lib |
See also:
Step 4 Unzip the PhixFlow Release
Unzip the PhixFlow release package into a temporary directory.
We will refer to the new PhixFlow release directory as $RELEASE
and its corresponding Tomcat directory as $TOMCAT.
Step 5 Install the New Webapp into Tomcat
Move the live PhixFlow installation directory, $TOMCAT/webapps/phixflow
, to an archive location.
For example on Linux: mv $TOMCAT/webapps/phixflow $ARCHIVE/phixflow-<current date>
Copy $RELEASE/webapp/phixflow
to $TOMCAT/webapps
.
For example on Linux: cp $RELEASE/webapp/phixflow $TOMCAT/webapps/phixflow
In the archive of the live installation, go to the $TOMCAT/webapps/phixflow/WEB-INF/classes/
directory. Copy the following files into the corresponding directory in the new PhixFlow webapp:
- phixflow-login.xml
- phixflow-datasource.xml
- phixflow-secret.xml
- phixflow-instance.xml
- logback.xml
- phixflow-logging.xml
For example on Linux:cp $CV_ARCHIVE/phixflow-<current date>/WEB-INF/classes, to $TOMCAT/webapps/phixflow/WEB-INF/classes
If you have configured PhixFlow to show your company logo, also copy $TOMCAT/webapps/phixflow/
gui/images/customerLogo.svg
. from the archive to the corresponding directory in the new PhixFlow webapp.If you have configured any soft links between Tomcat and PhixFlow directories, reinstate them; see Referencing Files and Images Via a Soft Link.
As part of the recommended PhixFlow installation, soft links are created from $TOMCAT/webapps/phixflow/datalink → [PhixFlow file system]/phixflow/datalink
. For further details go to Install the PhixFlow Webapp, but if you have followed the recommended installation, you can use one of the following commands to re-create the link ($WEBAPP is the name of the installed PhixFlow, in most cases just "phixflow").
Windows
Code Block |
---|
mklink /D C:\app\tomcat\webapps\$WEBAPP\datalink C:\app\phixflow\data\$WEBAPP\datalink |
Linux
Code Block |
---|
sudo ln -sf /opt/phixflow/data/$WEBAPP/datalink /opt/tomcat/webapps/$WEBAPP/datalink |
Step 6 Configure a Keystore
If you have not already done so, Configure a Keystore and Aliases. Use phixflow-secret.xml to specify the keystore details.
Step 7 Upgrade the Database
Run all migration scripts in sequence from the starting version to this version.
Note | ||
---|---|---|
| ||
Some of the scripts can generate warning messages, such as Caution: Changing any part of an object name could break scripts and stored procedures. Generally, warning messages do not indicate a problem. However, if you see any error messages, please contact your PhixFlow support team. |
Example for migrating Oracle
Code Block |
---|
cd $RELEASE/install/schema/oracle/migration/X.Y sqlplus myUsername/myPassword @migrate_schema_from_x_y_z_to_X_Y_Z.sql |
Example for migrating SQL Server
Code Block |
---|
cd $RELEASE/install/schema/sqlserver/migration/X.Y sqlcmd -S myServer\myInstance -U myUsername -P myPassword -d myDatabase -i migrate_schema_from_x_y_z_to_X_Y_Z.sql |
Example for migrating MariaDB (MySQL)
Code Block | ||
---|---|---|
| ||
cd $RELEASE/install/schema/sqlserver/migration/X.Y mysql -h myServer -u myUsername -p -D myDatabase source migrate_schema_from_x_y_z_to_X_Y_Z.sql |
Warning | ||
---|---|---|
| ||
Some MariaDB PhixFlow migration scripts create or use privileged functions and/or procedures, and must have privileges not required by the regular PhixFlow user. You can permanently allow functions like this to run by updating a setting in your my.cnf file. See Running non-deterministic functions in MariaDB for details. If you do not make this change, then you must make sure that either:
|
Step 8 Complete any Special Upgrade Instructions
Complete the Special Upgrade Instructions for all the intermediate releases between your current version and the version to which you are upgrading.
Step 9 Restore Soft Links and Re-start Tomcat
If you have configured soft links (also called symlinks or datalinks) between PhixFlow and Tomcat, recreate them; see Configuring Soft Links.
Restart the Tomcat service.
Step 10 Republish PhixFlow Stream Data
After upgrading, PhixFlow may need to republish data to its database. If you have very large streams this can cause slow initial performance. To ensure users are not affected, we recommend that you publish stream data immediately after upgrading.
- Log on to PhixFlow.
- Select
→ Other Options → Publish Streams.Insert excerpt _administration _administration nopanel true - Wait for the pop-up notification that publishing is complete.
Note |
---|
If you do not republish altered stream tables, PhixFlow will automatically start publishing data when the first user attempts to use a stream. This may cause slow performance until publishing is complete. |
Your PhixFlow upgrade is now complete and users can access the new version of PhixFlow.
For details about configuring PhixFlow once it is installed, see Administration.