Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This page provides a table listing support for the third party applications that are required to run PhixFlow at major releases:

  • A web browser (on the client side)
  • A database server
  • An application server
  • Java runtime environment

    Note

    Remember to update your database drivers to be compatible with the version of Java that PhixFlow requires.


The table given here table below also includes any special upgrade instructions that you should be aware of when planning to migrate to a new version. Please check for all special instructions between your current version and the new version. While the upgrade process for PhixFlow itself is quick, please use the table below to determine if you need to plan, with your IT department, upgrades to any other software.

Warning

We will discontinue support for Oracle 12c Release 1 (12.1) at the next major release.


PhixFlow Major Version



Databases Supported

Tomcat

version required


Java

version required

Runtime

Database 
Drivers compatible with:

Browsers

supported

Special upgrade instructions

PhixFlow Version


Oracle

MS SQL Server

Maria DB

IE1Chrome2

Firefox2

7.9

12c  (12.2.0.1 and 12.1)

2017

2016

10.18.58

Java 8 / JDBC 4.2 API

116659

Warning: This is the last major release to support Oracle 12c release 1 (12.1).

Mandatory: Due to changes to the logging setup, you must configure two new logging configuration files; see Configure logback.xml and phixflow-logging.xml.

7.812c (12.1

11g

2008 R2

-

7

7

5.9

11g or 12c

2008 R2

-

7

7

Upgrade 5.9.0

6.0

11g or 12c

2008 R2

10.0.14

7

7

7.0

12c

2012

10.0.14

8.5

8
)

2017

2016

10.18.58
116659

Mandatory: Upgrade to SQL Server 2016 or later.

Mandatory: There are incompatible changes at 7.8.0 to the webapp configuration files in $webapp/WEB-INF/classes - simply copying the configuration files from an earlier release will not work. We recommend that you create new configuration files by copying the relevant templates and re-applying the necessary changes. See the release notes for more information on the changes and files affected.

7.7

12c (12.1)

2017

2016

2014

2008

10.1

8.5


8
116659

We will support SQL Server 2008 until the end of 2018. At this point support for this database will be ended.

Mandatory: Upgrade to Java 1.8.0_151 or later and ensure that Java is configured to allow unlimited-strength security; see Install Java for details.

7.6

12c (12.1)

2017

2016

2014

2008

10.1

8.5


8
116659

Mandatory: Upgrade to Oracle 12c

Mandatory: Upgrade to MariaDB 10.1

We will support SQL Server 2008 until the end of 2018. At this point support for this database will be ended.

7.5

12c (12.1)

11g

2016

2014

2012

2008

10.1

10.0

8.5


8
116358

Advisory: If using Oracle upgrade to version 12c.

7.4

12c (12.1)

11g

2016

2014

2012

10.1

10.0

8.5


8
116256

If using Oracle 12c, update the phixflow-datasource.xml file to resolve an issue that can affect configuration imports; see Oracle 12c - edit phixflow-datasource.xml for details.

Excel File Collectors must quote worksheet names if they contain spaces and/or single quotes. This is not handled automatically by the upgrade process. See special notes for Excel file collectors at 7.4.0 for details.

7.3

12c (12.1)

11g

2016

2014

2012

10.1

10.0

8.5


8
116055Mandatory: Upgrade to Tomcat 8.5
7.2

12c (12.1)

11g

2016

2014

2012

10.1

10.0

8.5

8

7

8
115550

If using SQL Server, you need to update the SQLServer dialect specified in the phixflow-datasource.xml file. See: Release 7.2.0

7.1

12c (12.1)

11g

2016

2014

2012

10.1

10.0

8.5

8

7

8


11

10

55

50

Advisory: Upgrade to Tomcat 8.5

Advisory: If using Oracle upgrade to version 12c.

7.0

12c

11g

2016

2014

2012

10.1

10.0

8.5

8

7

8


11

10

53

47

Mandatory:  Install Java 8.

Advisory: Upgrade to Tomcat 8.5

Advisory: If using Oracle upgrade to version 12c.

6.0

12c

11g

2008 R2

10.1

10.0

8

7

7


8.053

47


5.9

12c

11g

2008 R2

-

8

7

7


8.0-

-

Please see additional special upgrade instructions for this release at Upgrade 5.9.0

5.8

11g

2008 R2

-

7

7


8.0-

-



1 The use of IE with PhixFlow version 7.0 onwards (i.e. with the Javascript GUI) is not recommended. The GUI has full functionality in this browser, but does not perform as well as in Chrome and Firefox.

2 We support all versions of Chrome and Firefox released in the 2 years prior to the release date. The versions tested at the time of each release are listed here. Should you have any problems with an earlier version than that listed, but within 2 years of the release date, or a later version than that listed, please contact the PhixFlow support desk.