A pipe is a connector that links two elements in a PhixFlow model and sends data from the input to the output. Pipes allows you to control which attributes and which records from the input are delivered by to the output, although in most cases - with minimal configuration - you will get all columns and the records from the current run.
The pipe must be enabled to make it active.
For advanced configuration, see Advanced Pipe Configuration.
Panel | ||||
---|---|---|---|---|
| ||||
A pipe joining a datasource to a data collector has no details to edit. All the configuration for the output data set occurs in the collector - either a database collector for a database datasource, or an HTTP collector for an HTTP datasource. |
Name
The name is used to refer to the pipe in other model elements.
Panel | ||||
---|---|---|---|---|
| ||||
The name can have no special characters except the underscore character '_', it has to start with a letter and cannot be an Attribute Function name. |
Type
There are 3 options available:
...
Data To Read
Specify what input data to use. There are 4 options available:
...
Panel | ||||
---|---|---|---|---|
| ||||
If the Only collect from same run flag is ticked, the pipe will only collect data from inputs in the same analysis run. This is only used when building a transactional model, and this configuration support several analysis runs going on at the same time without interfering with each other. |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
In some circumstances the input Stream may have Stream Sets that have dates in the future relative to the Stream Set being generated for the output Stream. This may happen, for example, if you have rolled back a number of Stream Sets on the output Stream but have not rolled back the corresponding Stream Sets on the input Stream, and have then requested that the output Stream is brought up to date. Some of the Stream Sets on the input Stream will have dates in the future relative to some of the Stream Sets you are rebuilding. By default, pipes will ignore any Stream Sets with dates in the future relative to the Stream Set you are generating. This is so that if you are rebuilding an old Stream Set the pipe will retrieve the same data on the rerun as it retrieved when the Stream Set was first built. Similarly, if you are running a Transactional Stream, it is possible that while your analysis run is taking place, other analysis runs which started after yours may have completed before yours. These will have generated additional Stream Sets on the input Stream with a future data relative to the date of the Stream Set you are generating. For Transactional input Streams it is possible to tell the pipe not to ignore these future Stream Sets by ticking the Read Future Data tick box on the Advanced tab. |
Static
Normally when a pipe requests data from a non-static input stream, that stream will first attempt to bring itself up to date, generating new stream sets as necessary, before supplying the data requested. However, if this field is ticked, the input stream will not run.
Mandatory
If ticked, when multiple Streams are being merged then there must be an input record from this Pipe for an output record to be generated by the output Stream.
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
If this is a push pipe with positive offsets and this flag is ticked then the notification to create another stream set will only be pushed along the pipe if the last stream set created contains at least one record. |
Multiplier
This causes the pipe to present each candidate set to the output stream in a different way than usual. The multiplier flag is on the Advanced tab of the form.
For each output record generated by a stream, the stream will get a set of records from each of its input pipes. If the multiplier flag is ticked on one of these, then the stream will generate an output record for each record from the set of records provided by the multiplier pipe. For each output record, each of the other input pipes will provide the same set of records as normal.
Filters, sorting and grouping, aggregating
Filters, sorting and grouping, and aggregating are configured through their own sections on the form:
...
The data being delivered by a pipe can be filtered.
Filters are made up of a set of clauses; each clause in turn contains a number of conditions. These conditions must be satisfied for data to be passed through the pipe.
Form Icons
The form provides the following buttons:
...
...
Add a clause or condition.
...
...
Delete a clause or condition.
...
...
Specifies that the value entered is a literal value. Click this icon to change this - to specify that the value entered be evaluated as an expression.
...
...
Specifies that the value entered is a evaluated as an PhixFlow expression. Click this icon to change this - to specify that the value entered be treated as a literal. Note : ["123", "234", "345"] looks like a literal value but it can be evaluated as an expression.
...
...
Filter on Current User
Sometimes when running analysis you want to select, from the source, only records belonging to the currently logged in user. To set a filter where, say, an attribute in the source Owner
equals the current logged in user, add a condition to the filter like this:
Owner
Equals _user.name
fx
Enter a list of values for an "Is In" or "Is Not In" filter
If you want to based on a list of values, use the Is in or Is not in comparators, then type the list of values into the comparison field as a comma separated list like this:
Country
Is in England, France, Germany
ABC
In this case you must NOT click the ABC icon to convert the value to an fx, because this will indicate that the value is a formula; it must be left as a literal value. If you do click the ABC icon, then the value must be entered like this:
...
Overview
A pipe is a connector that links two elements in a PhixFlow model and sends data from the input to the output. Pipes allows you to control which attributes and which records from the input are delivered by to the output, although in most cases - with minimal configuration - you will get all columns and the records from the current run.
The pipe must be enabled to make it active.
For advanced configuration, see Advanced Pipe Configuration.
Insert excerpt | ||||||
---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
| ||||
A pipe joining a datasource to a data collector has no details to edit. All the configuration for the output data set occurs in the collector - either a database collector for a database datasource, or an HTTP collector for an HTTP datasource. |
Basic Settings
Field | Description | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Enter a name. The name is used to refer to the pipe in other model elements. Pipe names default to The name:
| ||||||||||||||||
Enabled |
| ||||||||||||||||
Static | Normally when a pipe requests data from a non-static input stream, that stream will first attempt to bring itself up to date, generating new stream sets as necessary, before supplying the data requested. However, if this field is ticked, the input stream will not run. Pipes from collectors cannot be marked as static.
Pipes from collectors cannot be marked as static. | ||||||||||||||||
Mandatory |
If this is a push pipe with positive offsets and this option is ticked then the notification to create another stream set will only be pushed along the pipe if the last stream set created contains at least one record. This causes the pipe to present each candidate set to the output stream in a different way than usual. | ||||||||||||||||
Multiplier |
| ||||||||||||||||
Type | Select:
| ||||||||||||||||
Data to Read | Select the type of input data to use.
| ||||||||||||||||
Read Future Data | Use this option to exclude or include input streams sets that have future dates relative to the stream set you are generating. For details about how future stream sets occur, see Managing Future Stream Sets, above.
| ||||||||||||||||
Input | The name of the object at the start of the pipe. | ||||||||||||||||
Output | The name of the stream at the end of the pipe. |
Anchor | ||||
---|---|---|---|---|
|
In some circumstances the input stream may have stream sets that have dates in the future relative to the stream set being generated for the output stream. This may happen, for example, if:
- you roll-back some stream sets on the output stream
- but do not roll-back the corresponding stream sets on the input stream
- and then request that the output stream is brought up to date.
Some of the stream sets on the input stream will have dates in the future relative to some of the stream sets you are rebuilding.
By default, the Read Future Data check box is not ticked. This means pipes ignore any stream sets with dates in the future relative to the stream set you are generating. You want to ignore future stream sets when you rebuild an old stream set, because you want the pipe to retrieve the same data on the rerun as it retrieved when the stream set was first built.
When you run analysis on a stream with a transactional period, it is possible that as your analysis is still running, a different run can start and complete. This run can generate additional stream sets on the input stream with a future data relative to the date of the stream set you are generating. For transactional input streams, you want the pipe to use these future streams. To do this, tick the Read Future Data check box.
Filter
Filters are made up of a set of clauses; each clause in turn contains a number of conditions. These conditions must be satisfied for data to be passed through the pipe.
Tip |
---|
When the pipe Type is Lookup, the filter controls which data will be cached in memory. |
Field | Description | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cache Size
| Available when Type is Lookup. For lookup pipes, PhixFlow uses the pipe cache when it looks-up data from streams or database collectors. For efficiency, the records are cached (stored temporarily in memory) so that if the same set of records need to be looked up again they are readily available without going back to the database. Enter a number to set a limit on the data cache size available for the pipe. You need to estimate the largest number of records that the lookup pipe will return on a single read. Check whether PhixFlow is looking up:
If you do not set a limit for the cache, PhixFlow uses the system default set in System Configuration → System Tuning → Maximum Pipe Cache Size.
| ||||||||||||||||||||||||||||||||
Pipe View | Use this option to look up data from attributes that are present in a stream view on the input stream. Select a stream view from the list. If the input stream has no views, the list will be empty.
Use the pipe view to limit the attributes that the pipe reads when a stream has lots of attributes containing many data records but you only need data from a few attributes. Only the data for the attributes in the stream view are sent to the output stream. Pipe views are very useful:
To set up a pipe view:
| ||||||||||||||||||||||||||||||||
Include History Records |
| ||||||||||||||||||||||||||||||||
Condition | Select one of the options
To add more conditions, hover your mouse pointer over this field to display the button and add another condition to your filter. | ||||||||||||||||||||||||||||||||
Clause | Select an option from the list. PhixFlow adds more fields where you can:
| ||||||||||||||||||||||||||||||||
Filter Icons | Hover your mouse pointer over conditions or clauses to display:
| ||||||||||||||||||||||||||||||||
Cache Extraction Filter | A cache extraction filter allows you to further filter the data retrieved by a pipe. These are not commonly used, but are sometimes helpful when either:
For case 1, when using a lookup pipe, data retrieved is stored in a cache. See cache size for details. The cache extraction filter allows you, as you are processing a set of output records, to use different cached entries from the lookup for each of the records are you are processing. This is very fast compared to looking up from the source (i.e. going back to an external DB table or even another PhixFlow stream) for each output record. E.g. you want to look up the credit rating for a customer for a set of transactions - in the output, each transaction is represented by a single output record. You create an indexed lookup pipe using CustNo as the key for the index. This means that for each new CustNo you encounter in the data, all the credit rating entries for that CustNo would be retrieved by the pipe and placed into the cache. The credit rating for each customer is fully historied, so you get a number of entries for each CustNo. To get the relevant lookup entry for each output report (each transaction), you need to compare the transaction date of the output record to the dates of credit rating entries in the cache. So to extract the relevant record, you include a cache extraction filter in the form:
Cache extraction filters are entered free hand. The attribute names referenced must exist in a stream. This means that the each |
...
attribute must be one of:
|
...
|
...
A Pipe can be grouped and sorted by attributes of the input stream. These are set up in the Group/Order section of the Pipe form. In fact, this section is called Sort/Group for pull and push pipes, and Order/Index for lookup pipes.
The following fields are configured at the level of the pipe:
...
This setting is only available for lookup pipes.
Look-up pipes can be configured for fast "indexed" access to cached data collected from external tables, files or from other streams. Indexed access is controlled through configuring a pipe with an index and setting index expressions on grouping attributes. If the Type field on the Pipe is set to 'Look-up' then the field "Index Type" becomes available. This can have the value "None" meaning that there are no index keys or "Exact Match", "Best Match" or "Near Match" as described below:
- Exact Match: The pipe will retrieve data from its cache based on an exact match look-up with the values provided after evaluating the index expressions on the "Group By" attributes.
- Best Match: The pipe will retrieve data from its cache based on a "Best Match" look-up after evaluating the index expressions on the "Group By" attributes. Note that the last Group By Attribute with a key expression is used for the best match lookup. The index keys on any Group By attributes with a lower sequence number are used as an initial "Exact Match" to find the set of data on which to do the "Best Match". The "Best Match" is defined as the longest key value which matches the evaluated index expression.
- Near Match: The pipe will retrieve data from its cache based on a "Near Match" look-up after evaluating the index expressions on the "Group By" attributes. Note that the last Group By Attribute with a key expression is used for the near match lookup. The index keys on any Group By attributes with a lower sequence number are used as an initial "Exact Match" to find the set of data on which to do the "Best Match". When "Near Match" is selected, an additional field appears where you can enter an expression which should evaluate to a number representing the allowed number of edits (e.g. deletions, insertions, substitutions and transpositions) which can be made when comparing the result of the index expression to the index key in order to achieve a match.
For example if the index key is "Smyhte" and the result of the index expression is "Smith" this would still be a match providing that the allowed number of edits is 3 or more (i.e. substitute the 'i' for a 'y', transpose the 't' and the 'h' and then insert an 'e' at the end).
Form: Grouping Attribute Details
The following fields are configured for each grouping attribute:
...
This field is only available for lookup pipes where you have selected indexing.
If the pipe is configured as a Look-up with an index match type set, this field becomes available. Look-up pipes can be configured for fast "indexed" access to cached data. This data is collected from external tables, files or from other streams. Indexed access is controlled through configuring a pipe with an index and setting index expressions on "Group By" attributes here.
...
Aggregate Attributes define the aggregated properties that are available when data is read from an aggregating Pipe. Note that Aggregate Attributes are not available on Pipes from Database Collectors (any aggregation can be performed in the query SQL), nor are they available on Pipes from File Collectors.
Possible aggregate values are counts, summations, averages and maximum or minimum values of Stream Items grouped in the Group/Order tab of the Pipe.
...
Only aggregate attributes which can be aggregated. For example, do not try to sum an attribute which contains text.
...
The following fields are available in the Basic Settings section if you set Data To Read = Custom:
...
- Only collect from same run is not ticked
- Max Stream Sets is blank or zero
- Historied is not ticked
Advanced section
The following fields are configured in the Advanced section:
Normally, when a pipe tries to read from an input stream that contains an incomplete stream set, PhixFlow will attempt to complete the stream set before passing data down the pipe. However if the stream is static (i.e. the stream has its 'static' flag ticked) or is effectively static (i.e. all of the pipes reading from it in this analysis run are static) then, instead of completing the stream set, an error message is produced indicating that you cannot read from this stream because it contains an incomplete stream set.
If you do not want this error message to be produced when reading from static (or effectively static) streams, but would instead prefer PhixFlow to ignore the incomplete stream sets, then you must tick this box on all pipes that will read from the input stream in this analysis run. If there are multiple pipes that read from the input stream during this analysis run and even one of the pipes does not have this box ticked then you will not be allowed to read from the stream and the error message will be produced.
Pipes which are not used in the current analysis run (for example where they lead to streams on branches of the model which are not run by the current task plan) have no effect on whether or not the error message is produced.
The cache is used when carrying out lookups from streams or database collectors. When doing a lookup, there are two common scenarios:
- The pipe does a single lookup onto a stream or database table to get a large number of records in one go (e.g. 10,000 records)
- The pipe does many lookups, getting a small number of records for each lookup (e.g. 10 records at a time).
In case 2, the results returned are typically based on a key value, e.g. an account number. This will be used in the filter of the pipe, if you are reading from a stream, or in the query, if you are reading from a database collector. For example, the query in a database collector will include the condition:
Code Block |
---|
WHERE AccountNumber = _out.AccountNum |
For efficiency, the records are cached (stored temporarily in memory) so that if the same set of records need to be looked up again they are readily available without going back to the database.
This field allows you to set a limit on the size of the cache. Setting a limit is important because if you do not, the cache can become very large and consume a lot of memory, which can lead to a slow down in both your tasks and those of other users of PhixFlow.
To set the cache size, try to estimate the largest number of records that the lookup pipe will return on a single read.
If you do not set a limit, it will default to the system-wide default, specified in the Maximum Pipe Cache Size in the System Tuning tab of the System Configuration.
bgColor | #e6f0ff |
---|---|
titleBGColor | #99c2ff |
title | Cache warnings and errors |
If a single read brings back over 90% of the specified cache size, a warning message will be logged to the console.
If a single read brings back 100% or more of the cache size, a second warning message will be generated. If the Enforce Cache Size limit flag is ticked in System Configuration, instead of a warning an error will be generated, and the analysis run will stop completely.
Code Block | ||
---|---|---|
| ||
The Pipe "stream_name.lookup_pipe_name" cache is 100% full (the cache size is 10). |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Every time the lookup pipe is referenced, PhixFlow calculates the values of all of the variable elements of the query or pipe filter, and checks if it already has a set of data in the cache retrieved using this set of variable values. If so the data is immediately returned from the cache. Otherwise, a new set of data is read from the stream of collector. If adding the new records to the cache would cause it to exceed the maximum cache size, previously cached results are removed to make enough room for the new results. |
The pipe view is used in two contexts.
During lookups
Pipe views can also be used on lookup pipes to limit the fields that are returned by the lookup request. This is most useful in the scenario where the you want to read and cache data on a lookup pipe from a stream that has lots of attributes but where only a small number of attributes are actually required. You can simply create a new view on the source stream listing only the attributes needed, then specify it as the pipe view on the lookup pipe. Only those attributes specified on the view will then be loaded.Without a pipe view, the pipe will load and cache all of the attributes from the stream which may consume a significant amount of free memory if there are a large number of records.
During File Export
When sending data to a file exporter only those fields specified on the pipe view will be exported. If no pipe view is supplied then all fields will be exported.If the file exporter is configured to export to Excel or to HTML, and no Excel template is specified on the exporter, then the pipe view will be checked to see if an Excel template has been specified there. This template will then be used as part of the export. See the description of file exporters for further details. If an Excel template has been specified on the exporter then this will override any template specified on the pipe view.
If the file exporter is configured to export to HTML and the pipe view is a chart view then the output will be a picture of the chart in PNG format.
Max Records To Read
The Execution Strategy determines how this pipe should be implemented. See the section on Directed Merge Strategy
Max Workers
This field is only available if Strategy = Directed
The maximum number of concurrent worker tasks.
If blank, this defaults to 1.
This field is only available if Strategy = Directed
The number of key values to read for a single worker task (which runs a single select statement).
If blank, this defaults to 1000. This is the maximum value that can be used when reading from an Oracle database.
|
Filter Examples
Filter on Current User
Sometimes when running analysis you want to select, from the source, only records belonging to the currently logged in user. To set a filter where, say, an attribute in the source Owner
equals the current logged in user, add a condition to the filter like this:
Owner
Equals _user.name
fx
Enter a list of values for an "Is In" or "Is Not In" filter
If you want to based on a list of values, use the Is in or Is not in comparators, then type the list of values into the comparison field as a comma separated list like this:
Country
Is in England, France, Germany
ABC
In this case you must NOT click the ABC icon to convert the value to an fx, because this will indicate that the value is a formula; it must be left as a literal value. If you do click the ABC icon, then the value must be entered like this:
Country
Is in ["England","France","Germany"]
fx
Sort/Group
For lookup pipes this section is called Order/Index.
Use this section to group and sort data as it comes through the pipe. This section has:
- a toolbar with standard buttons
- a grid that lists the attributes that you want to sort or use to group
- below the grid are the following options:
Field | Description |
---|---|
Maximum Number of records per Group | Enter an upper limit for grouped records. When collating the input records into groups, PhixFlow uses the specified sort order. When it has added the maximum number of records, any more records for the group are ignored. This can be useful if you want the most recent record for an attribute that has many records.
|
Index Type | Available when Type is Look-up. Look-up pipes can be configured for fast "indexed" access to cached data collected from external tables, files or from other streams. Indexed access is controlled through configuring a pipe with an index and setting index expressions on grouping attributes. If the Type field on the Pipe is set to 'Look-up' then the field "Index Type" becomes available. This can have the value "None" meaning that there are no index keys or "Exact Match", "Best Match" or "Near Match" as described below:
|
Using the Sort/Group Grid
To add a stream attribute to the list:
- click
to open the list of attributes in the input streamInsert excerpt _attributes_show _attributes_show nopanel true - drag a stream attribute into the grid.
To remove an attribute, click
Insert excerpt | ||||||
---|---|---|---|---|---|---|
|
To set the sort or group properties for an attribute, double-click its name in the grid. If you want to create a new attribute that is not present in the input stream, in the section toolbar, click
Insert excerpt | ||||||
---|---|---|---|---|---|---|
|
Field | Description | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Attribute | For input stream attributes, PhixFlow displays the attribute name. (Read-only) For a new attribute, enter a name. | ||||||||||||||||
Order | Enter the number for the order the attribute appears in the grid and the order in which it is processed. Other attributes are renumbered. | ||||||||||||||||
Direction | Select the sort order
| ||||||||||||||||
Group |
If this attribute is part of the candidate key set, you must tick the Group check box. Otherwise, the attributes will be used only to sort the data in the candidate set. | ||||||||||||||||
Index Expression | This field is available for lookup pipes with an Index Type option selected. Look-up pipes can be configured for fast "indexed" access to cached data. This data is collected from external tables, files or from other streams. Indexed access is controlled through configuring a pipe with an index and setting index expressions on "Group By" attributes here. | ||||||||||||||||
Audit Summary | See Common Properties. |
Tip |
---|
In some cases, you may have a pipe connected to a database collector, which pulls data from an external database table. In these cases, the fields in the database must have matching attribute names in the output stream. You can refer to it using the format |
Aggregate Attributes
Use this section to define the properties of data that you want to combine as it comes through the pipe.
Note |
---|
You cannot aggregate data from attributes if the pipe's input is from: If you need to aggregate data from a database collector, you can use an SQL query. |
This section has:
- a toolbar with standard buttons
- a grid that lists the attributes that you want to aggregate.
Using the Aggregate Attributes Grid
To add a stream attribute to the list:
- click
to open the list of attributes in the input streamInsert excerpt _attributes_show _attributes_show nopanel true - drag a stream attribute into the grid.
To remove an attribute, click
Insert excerpt | ||||||
---|---|---|---|---|---|---|
|
To set the properties for an aggregate attribute, double-click its name in the grid. PhixFlow opens the attribute's sort properties:
Field | Description |
---|---|
Stream Function | Select an function to combine stream data records.
See Aggregate Function for details. Make sure the function matches the data in the attribute. For example, you cannot Sum text. |
Attribute | Select the stream attribute aggregated from the list of attributes in the input stream. PhixFlow does not use the value in this field if the Aggregate Function is Count. |
Name | Enter the name for the aggregated attribute. This can be the same as the original attribute. |
Order | The order of the aggregate attribute in the output stream. |
Advanced
The following options are available when the pipe Type is Push or Pull. Allow Incomplete Stream Sets is also available when the pipe Type is Lookup.
Field | Description | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Expected |
| ||||||||||||||||||||||||||
Allow Incomplete Stream Sets |
PhixFlow cannot complete a stream set if:
Pipes that are not used in the analysis run do not try to complete a stream set, so will not report an error. (Unused pipes can occur if they lead to streams on branches of the model that are not being run.) | ||||||||||||||||||||||||||
Buffer Size | Enter a number for the buffer size used to perform the stream calculation. If a large amount of data is being processed, then setting a large buffer size will give better performance. | ||||||||||||||||||||||||||
Max Records To Read | Enter a number for the maximum number of records that should be read down this pipe. The pipe may read more than this number of records if it is configured to carry out multiple reads simultaneously. For example:
| ||||||||||||||||||||||||||
Strategy | Select an option to specify how this pipe should be implemented. See the section on Directed Merge Strategy
| ||||||||||||||||||||||||||
Max Workers | This field is available when Strategy is Directed Enter the maximum number of concurrent worker tasks. When no value is specified, this defaults to 1. | ||||||||||||||||||||||||||
Worker Size | This field is available when Strategy is Directed Enter the number of key values to read for a single worker task, which runs a single select statement. When no value is specified, this defaults to 1000. This is the maximum value that can be used when reading from an Oracle database. | ||||||||||||||||||||||||||
Log Traffic |
|
Custom Data to Read
Anchor | ||||
---|---|---|---|---|
|
The following properties are available in Basic Settings when you set Data To Read to Custom.
Field | Description | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Only collect from same run | Every time the analysis engine runs, all of the stream sets that are created by all of the streams affected by that analysis run are given the same Run ID.
| ||||||||||||||||
From Offset | Enter the offset applied to the start of the collection period, relative to the period in the output stream that requires populating. | ||||||||||||||||
To Offset | Enter the offset applied to the end of the collection period, relative to the period in the output stream that requires populating. | ||||||||||||||||
Max Stream Sets | Enter the number of stream sets to be retrieved from the input stream. For a push pipe with positive offsets. enter the maximum number of stream sets that can be created i.e. the maximum number of cycles this pipe can initiate. | ||||||||||||||||
Historied |
For example, if:
the pipe reads data from the input stream for the period 17/10/07 - 18/10/07. |