This page provides details of the properties for the open screen node and associated expressions. These are part of actionflows.
Overview
Use an Open Screen action node to open new screens within PhixFlow. To set the actionflow to close the active dashboard on completion, on the top right of the canvas, tick Close Parent Dashboard.
Example
The above video shows a basic actionflow to open a screen from a button. To open a screen:
- Right click on the button and click Add Actionflow
- Name the action
- Drag the screen you want to open onto the main body of the actionflow. You have just created an open screen node.
- Now we need to wire up an input to initiate the actionflow
- Click Add next to the inputs
- Name the new input connection point and select driving.
- Click create connection point
- Click on the on click input. This will start the actionflow when a user clicks on the button.
- Click connect input to finish setting up the actionflow
- Go back to the first screen to test to see if it works.
Properties Tab
If this item is within or belongs to another, its parent name is shown here. See the Parent Details section on the Common Properties page for more details.Parent Details
Basic Settings
Field | Description |
---|---|
Name | Enter the name for the action node. |
Show in the Repository | An application can have many actionflows, and an individual actionflow can have many nodes. This can lead to many items being listed under Actionflow in the repository. Use this option to omit the node from the repository. to display this node in the repository. to omit this node from the repository. |
Screen | Select a dashboard that the action will open. The dashboard can be selected using the drop down or List Screens. If the screen has not been created yet, create one using Add New. A warning symbol appears on the node if a screen has not been selected. |
Model Validation Status | When you save changes to the properties of a table or view attribute, PhixFlow validates that the properties are set correctly. If there is an issue with the properties, PhixFlow indicates the status of the validation check:
When a table or view attribute has validation errors, PhixFlow also reports that the parent application and package have errors. PhixFlow can process data from tables or view attributes that have validation errors. The validation checks help you to configure tables and view attributes so that PhixFlow can continue to run efficiently. For example, PhixFlow reports an error if a table has no Data Retention option set because it can affect performance when all old tablesets are retained, To run validation checks on all tables, view attributes, applications and packages, use Administration Menu → More → Validate Model Objects. |
Input Connection Points
Each open screen node has 1 primary input connection point by default called 'screen'. Connecting to this connection point opens the screen and allows the user to optionally map the following screen properties. (may not happen for v9)
Property | Type | Default Values if not set | Description |
---|---|---|---|
height | Number | find out | Sets the height of the screen |
width | Number | find out | Sets the width of the screen |
top | Number | find out | Sets the top position of the screen relative to the window |
left | Number | find out | Sets the left position of the screen relative to the window |
maximised | Boolean | whatever is set on the screen properties |
|
Once a screen has been attached to the open dashboard node an input connection point for each form on the screen is created with a role of component. Each input connection point automatically has any data fields on the form (dynamic text or form fields) added as attributes. These attributes can be mapped to and supplied with data.
Each input connection point has the following properties:
Field | Description |
---|---|
Name | The name of the input connection point |
Role |
|
Open Mode |
|
Attributes | A list of attributes available on the input connection point. These directly link to the fields available on the form. Component connection points display attributes available on the associated form. Primary connection points display the screen properties as attributes. |
Output Connection Points
If the screen attached to the node contains start phase buttons (buttons with the action type 'Start Phase') the output connection point section will appear.
Properties - to do
We recommend that you always enter a description to explain the purpose of this item.Description
See the Common Properties page, Audit Summary section. Audit Tab
Audit Summary
Learn More
For links to all pages in this topic, see Understanding Actionflows.