Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Insert excerpt
_Banners
_Banners
nameactionflow
nopaneltrue

Overview

Use the input and output connection points on nodes in an actionflow to wire the nodes together. 

  • From the Inputs pane on left, into the actionflow.
  • From one node to another within the actionflow. 
    Hover your mouse pointer over a node and click Add Output to add an connector to another node.
  • From a final actionflow node to the Outputs pane on the right of the actionflow.

Connection points available depend on the purpose of the node.

  • Output connection points: 
    • Calculate
    • Gate
    • View

Nodes without an output connection represent:

When you wire nodes together, you need to map which attributes pass through to the next node. To change the mapping, click on the connector to open the Mapping window.

Node properties have sections for Input Connection Points and Output Connection Points on the node. Double-click on a listed connection point to open its properties.

Note

The properties available for connection points vary depending on the node on which they occur. 

Driving and Lookup Connection Points

  • If you connect a node via a driving connection, records are returned individually to the connected node and flow one by one through the remainder of the actionflow.
  • If you connect a node via a lookup connection, the records are returned as an array within one recordset. Nodes wired via lookup connection points require both:
    • Data Attributes: add attributes from the view. PhixFlow looks-up data from these attributes. 
    • Request Attributes: when the actionflow runs, PhixFlow returns the data to these attributes.

The following sections explain the properties for input and output connection points.

Connection Points 
Anchor
input
input

Open the 

Insert excerpt
_property_settings
_property_settings
nopaneltrue
 for each connection point (input, lookup, output) by clicking on the node.

Insert excerpt
_property_tabs
_property_tabs
namebasic-h
nopaneltrue

Insert excerpt
_parent
_parent
nopaneltrue

Basic Settings

FieldDescriptionConnection Point Found On
NameThe name of the Actionflow.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Insert excerpt
_output
_output
namecaps
nopaneltrue

Action Phase

The 

Insert excerpt
_action_phase
_action_phase
nopaneltrue
 that the connection point is in. See Actionflow Phases.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Insert excerpt
_output
_output
namecaps
nopaneltrue

Validation

FieldDescriptionConnection Point Found On
Minimum RecordsThe minimum number of records that the Actionflow needs to run. If the received records are not above the minimum set, the Actionflow will not run.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Maximum RecordsThe maximum number of records that the Actionflow is permitted to runIf the received records exceed the maximum set, the Actionflow will not run.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Input Parameters

FieldDescriptionConnection Point Found On
Name

The name of the input parameters (attributes) mapped into the Actionflow.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Insert excerpt
_output
_output
namecaps
nopaneltrue

TypeThe data type (e.g. integer) of each input parameter (attribute) mapped into the Actionflow.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Insert excerpt
_output
_output
namecaps
nopaneltrue

Default Value

Available in PhixFlow 11.1.1+

A value or expression that is evaluated when no value is mapped to the attribute, or if the value is null or unavailable (e.g. if the user did not have permission to see it).

For referencing attributes, use the notation in.attributeName.

Note: Default value expressions do not use the order they are set in and are automatically resolved in the appropriate order based upon other attributes they reference.

Insert excerpt
_input
_input
namecaps
nopaneltrue

Insert excerpt
_lookup
_lookup
nopaneltrue

Insert excerpt
_output
_output
namecaps
nopaneltrue

Input Connection Points

See Input Connection Points.

Input Connections

A grid of Input Connections. 

The following properties are available for Input Connections for open Screen Action nodes only.

FieldDescription
Role

 Specify whether the actionflow will provide data to the view or screen being opened.

  • Primary: selected by default.
    The view or screen opens regardless of data. 
  • Component: 
    The actionflow provides data to the view or screen when it opens.
Type

Available when Role is Component.

Specify the type of connection:

  • Insert excerpt
    _driving_input_connection_point
    _driving_input_connection_point
    nopaneltrue
    : there can be only one of these.
  • Insert excerpt
    _request_input_connection_point
    _request_input_connection_point
    nopaneltrue
    : there can be multiple of these
Open Mode


Excerpt
namescreenInputConnections

Available when Role is Component. For example,

When a screen opens, specify how data fields will display:

  • Insert data fields are cleared and variables are passed to the screen from the actionflow, the screen is then ready for the application user to add new data. Typically used for adding new data.
  • Update Variables created in the actionflow are set on the screen, any filtering is applied, data is retrieved from the server and displayed in the fields. Note the values set by the actionflow are persisted. Typically used for updating existing data.
  • Change Fields Variables passed to the screen are set. Typically used to set a value on one screen from another.


Attributes

A list of attributes available on the input connection point. These directly link to the fields available on the form.

  • Primary connection points display the screen properties as attributes.
  • Component connection points display attributes available on the associated form.


HTML Comment

Not yet implemented - and may need to be on the input connection page.
Each open screen node has 1 primary input connection point by default called 'screen'. Available when Input connection point Role is Primary, optionally set:

FieldTypeDefault Values if not setDescription
HeightNumber
Sets the height of the screen
WidthNumber
Sets the width of the screen
TopNumber
Sets the top position of the screen relative to the window
LeftNumber
Sets the left position of the screen relative to the window
MaximisedBooleanwhatever is set on the screen properties
  • True will open the dashboard in its maximised state.
  • False will open the dashboard in its minimised state and will use the above properties.

When you connect an open screen node to a screen, PhixFlow automatically adds an input connection point for each form on the screen. The input connection point is automatically set to:

  •  Role Component.
  •  Attributes: all data fields and dynamic text fields are added.
    This means you can map to the attributes and pass data to them.

Data Attributes

This section has a toolbar with standard buttonsThe grid contains a list of the attributes that will pass through the wire into this node. All nodes can have a driving input connection, which passes data records one-by-one into the node.

To refer to these attributes in an expression, specify the names of the connection point and attribute with the syntax:

Code Block
connectionpointname.attributename

Double-click on an attribute in the list to display tje properties related to this node and connection. This can include Name, Type, Component, Primary Key etc.

  • To create a new attribute: click 
    Insert excerpt
    _add
    _add
    nopaneltrue
     and set the Name and Type; see Attribute.
  • To add an existing attribute to this list, open the list of attributes and drag one onto the grid.
  • To open its properties, double-click one of the listed attributes.
  • To remove an attribute, select one and click 
    Insert excerpt
    _delete
    _delete
    nopaneltrue

Insert excerpt
_structured_data
_structured_data
nopaneltrue

Request Attributes

Available for View, Gate and Calculate nodes, which can have Lookup connection points.

This section has a toolbar with standard buttonsThe grid contains a list of the attributes that you want to lookup from another table. Lookup connections pass a complete set of records into the node. 

To refer to these attributes in an expression, specify:

Code Block
req.attributename

Double-click on an attribute in the list to display its properties related to this node and connection. This can include Name, Type, Component, Primary Key etc.

  • To create a new attribute: click 
    Insert excerpt
    _add
    _add
    nopaneltrue
     and set the Name and Type; see Attribute.
  • To change its properties, double-click an attribute in the list; see View Attribute
  • To delete an attribute, right-click and select 
    Insert excerpt
    _delete
    _delete
    nopaneltrue
    .

Insert excerpt
_structured_data
_structured_data
nopaneltrue

Insert excerpt
_audit
_audit
nopaneltrue

Output Connection Points 
Anchor
output
output

This section is not available for nodes that do not require output connections because: the node represents the end of actionflow processing: Save, Open Screen, Open URL, and Analysis nodes.

For all other nodes, the output connection point has an expression that specifies the logic to control whether or not records flow to the next action node. The syntax for a driving connection is:

Code Block
connectionpointname.attributename

The syntax for a lookup connection is:

Code Block
req.attributename

If the expression evaluates to true for the record flowing through the node, it will pass through the connection point onto the next node in the sequence. 

Insert excerpt
_property_toolbar
_property_toolbar
nopaneltrue

Insert excerpt
_property_tabs
_property_tabs
namebasic-h
nopaneltrue

Insert excerpt
_parent
_parent
nopaneltrue

Basic Settings

Field

Description
NameEnter a name for the output connection point
Order

Enter a number to indicate the order in which this expression will be run.
Remember that an expression that generates a value must run before an expression that uses the value.

Tip

The order is very important for exclusive gateway nodes, as the records pass through the first output connection that meets the expression condition.


Expression

Enter an expression that evaluates to true or false to specify whether or not records pass through this connection point. To work in a larger popup window, click 

Insert excerpt
_editor_expand
_editor_expand
nopaneltrue
.

See also:


Note

Gateways can have an unlimited number of output paths. If the Gateway Action Configuration is Exclusive, records only pass through the first output path where the expression condition is met.

Insert excerpt
_audit
_audit
nopaneltrue

Actionflow Wire Properties

Wire properties do not include the name. 

Basic Settings

FieldDescription
InputThe name of the node at the start of this wire.
Input Connection Point

The name of the connection point.

OutputThe name of the node at the end of this wire.
Output Connection PointThe name of the connection point.

To remove a mapping, right-click and select  Delete Mapping

Input Mappings

The left grid contains a list of attributes available from the input.  

Output Mappings

The right grid contains a list of attributes available to map to in the output.   

Insert excerpt
_audit
_audit
nopaneltrue

Live Search
spaceKey@self
additionalnone
placeholderSearch all help pages
typepage

Panel
borderColor#00374F
titleColorwhite
titleBGColor#00374F
borderStylesolid
titleSections on this page

Table of Contents
maxLevel3
indent12px
stylenone


Learn More