System Logging Configuration
Former user (Deleted)
Zoe Baldwin
Chris Welford
This page is for administrators who want to configure options related to logging.
There are several way to access system logging configuration:
- In the header bar, click
Administration →
System →
Logging
- Open the
System Console. In the top right of the console window, click
System Logging Configuration.
PhixFlow opens the System Logging properties tab.
Log file names can be up to 250 characters long. See Configure logback.xml and phixflow-logging.xml in Install the PhixFlow Webapp for information about setting log file names.
For information about the properties toolbar, and about the sections Parent Details, Analysis Models, Description and Audit Summary, see Common Properties. We recommend you always add a Description that explains the purpose of the item you are creating.
For a full list of all the PhixFlow property tabs and windows, see Properties, Windows, Menus and Toolbars.
Field | Description |
---|---|
Log Frequency | |
Database Reporting Frequency | Enter the number-of-records frequency with which records are reported. For example, enter 50000 to write a message to the log after every 50000 records have been inserted. |
File Reporting Frequency | Enter the number-of-records frequency with which records are reported from file imports. For example, enter 1000 to write a message to the log after every 1000 records have been imported. |
Maximum Debug Messages | When the options set in system logging cause a message to be written to a log file, the message has the type DEBUG. If several of these options are ticked for a large analysis run, PhixFlow can generate very large log files. To limit the size of log files, enter a number to indicate the maximum number of debug messages that can be written to the log file. |
Debugging On |
|
Log Service Requests |
When you select this option, PhixFlow generates very large log files. Service requests include the data being handled, which could include sensitive data about your company, personal data and other information that should be protected. This type of information may be governed by data security controls in your company. If you need to share these log files with other people, either within your company or with third-parties (such as PhixFlow IT support or consultants) check them carefully to ensure they contain no sensitive information. |
Allow Pipe and Data Handler Logging | |
Allow Logging | Changing this option requires the Enable System Logging privilege.
With logging enabled you can then:
|
Pipe Logging | |
Log Input Multiplier Messages |
|
Log Pipe Traffic |
|
Log Pipe SQL |
|
Log Lookup Pipe traffic |
|
Log Lookup Pipe SQL |
|
Collector/ Exporter Logging | |
Log File Collector Traffic | ![]() |
Log Database Collector Statements | ![]() |
Log Database Exporter Statements | ![]() |
Log HTTP Collector Connection Details |
|
Log HTTP Exporter Connection Details |
|
Maximum HTTP Log Length | Enter the maximum number of characters from the request and response body to log in the debug message. |